Microsoft word - material safety data sheet_2009_.rtf
Material Safety Data Sheet
(Originated from OSHA Hazard Communication Standard, 29CFR1910.1200)
1. Product Identification Product Name: Lithium Thionyl Chloride Battery
Chemical Reaction: 4Li + 2SOCl2 → 4LiCl + S + SO2
Models (IEC Standard): XL-050F(ER14252), XLP-050F(ER14252), XL-050H(ER14252),
XL-050FC(ER14252), XL-055F(ER14335), XLP-055F(ER14335), XL-060F(ER14505), XLP-060F(ER14505), XL-060H(ER14505) XL-100F(ER17500), XL-140F(ER26500), XL-145F(ER26500), XL-200F(ER32L615), XL-205F(ER32L615), XL-210F(ER33L65)
2. Composition/Information on Ingredients XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea
Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
3. Health Hazard Standard
Signs or Symptoms of Exposure: Unless the electrolyte is exposure or rupture, there are
no symptoms. When exposed to internal contents, corrosive fumes will be very irritating to skin, eyes, and mucous membranes. Continuous exposure can cause sign of non-fibrotic lung injury and membrane irritation.
Medical Conditions Generally Aggravated by Exposure: There may occur eczema, skin
allergies, lung injuries, asthma, and other respiratory disorders when exposed.
4. Emergency First Aid Procedures Eye Contact: Flush with Running Water for at Least 15 Minutes. Hold eyelids apart. Seek
Skin Contact: Rinse with plenty of running water. If burns develop, seek medical treatment. Inhalation: Remove to fresh air. If necessary, administer oxygen and seek medical treatment.
Ingestion: Find immediate medical treatment. 5. Fire and Explosion Hazard Standard
Fire and Explosion Condition: Continuously exposed to above 100℃ (212℉) caused by
abnormal environmental condition. Drop contents of lithium metal to water.
Special Fire Fighting Procedures: Do not use water, sand, carbon dioxide, or soda ash
extinguisher. Wear protective breathing apparatus and protective garments.
Unusual Fire and Explosion Hazards: Do not short circuit, recharge, over-discharge,
puncture, incinerate, crush or expose to temperature above the temperature rate of the battery.
XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea
Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
6. Accidental Release Measures None under normal use conditions. If contents leak, observe the following instructions Protection for person Use full protective equipment to avoid breathing vapors or touching liquid. Removing procedure Put the leaked battery into large container filled with water. Rinse the leaked liquid with water. Area Evacuate the area except for operators. After above procedures, ventilate the contaminated area. 7. Precautions For Safe Handling and Use Working Steps when Material is Spilled or Released: Do not breathe vapors nor touch
Waste Disposal Method: Neutralize spill with soda lime, seal leaking battery and soda lime
in plastic bag and dispose of as hazardous waste.
Precautions in Handling and Storage: Do not short circuit or expose to temperature rates
of the battery. Do not recharge, over-discharge, puncture, or crush.
Other Precaution and/or Special Hazards: Do not store batteries in high humidity and
environment for long periods because such condition can cause higher self-discharge.
8. Control Standard Respiratory Protection: As any fire situation is happened, use self-contained breathing
apparatus if a cell vent or fire occurs.
Eye Protection: Safety glass are recommended Protective Gloves: In case of leakage, wear gloves. Other Protective Clothing: In the event of leakage, wear chemical apron. Ventilation:
Local Exhaust: Yes Medical: N/A Special: N/A Other: N/A
XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea
Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
9. Physical Characteristics
When open by force, the ingredients hydrolyzed to
form SO2 and HCl upon contact with water.
10. Reactivity Standard Stability: Stable (hermetically sealed type, used in recommended conditions) Condition to Avoid: Give too much force, drop, crush & disassemble, short-circuit,
recharge, fire & heat above 100℃ (212℉), incinerate and etc.
Incompatibility: Do not expose internal contents to water Hazardous Decomposition Products: SO2, HCl, LiOH and H2 Hazardous Polymerization: Will not occur. 11. Toxicological Information N/A 12. Ecological Information N/A 13. Disposal Different to the policy of each country. Normally, it is not allowed to throw away.
- Proper Shipping Name: Used Lithium Batteries - UN Number: UN3090 - Hazard Classification: Class 9(Miscellaneous) - Packing Group : Ⅱ - Labels Required: Miscellaneous Hazardous Waste - Disposal Code: D003
XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea
Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
- Other: All lithium thionyl chloride batteries should be disposed of by a proper disposal
14. Transportation Regulation IATA / ICAO (International Air Transport Association / International Civil Aviation Organization) US DOT (US Federal Department of Transportation) ADR / RID (European Road and Railroad Transportation) 1. UN Number: UN3090 / UN3091 2. Shipping Name: “Lithium Metal Batteries” 3. Packing instruction: 968
- Small size: 1/2AA, 2/3AA, AA, A and 1/10D
Hazard Classification: No Class 9 (Miscellaneous) Packing Group: Part I : small sizes Î Non-Dangerous goods packing based on special provision A45
Passenger cargo: Max. 2.5Kg per carton Cargo aircraft only: Max. 35Kg per carton
Special Provisions: 188, 230, 310, 636 of ADR/RID 2003 or A45, A48, A88, A99 of IATA
Dangerous Goods Regulations 2009 50th (UN No. 3090, 3091)
- Big size(C and D)
Hazard Classification: Class 9 (Miscellaneous) Packing Group: Part II : big sizes Î Dangerous goods packing.
Package: 4G box(Group II) with special documents. Passenger cargo: Max. 2.5Kg per carton Cargo aircraft only: Max. 35Kg per carton
- Each shipment must be accompanied with a mark and a document indicating that the
package contains lithium batteries and that special procedures should be followed in the event a package is damaged.
Transportation of Lithium Batteries
Basically, regarded as dangerous goods based on above regulations when lithium batteries are delivered via air. However, Lithium metal cells and batteries offered for transport are not subject to other provisions of these Regulations if they meet the following:
1) For a lithium metal cell, the lithium content is not more than 1g 2) For a lithium metal or lithium alloy battery, the aggregate lithium content is not more
3) Each cell or battery is of a type proved to the requirements of each test in the UN
XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea
Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
Manual of Tests and Criteria, Part III, subjection 38-3;
4) Cells and batteries are separated so as to prevent short circuits and are packed in
strong packages, except when installed in equipment.
- XenoEnergy lithium metal batteries, 1/2AA, 2/3AA, AA, A and 1/10D meet above Special - XenoEnergy lithium metal batteries, C and D do not meet above Special Provisions No. 1 and 2. Thus, special package is necessary based on packaging group II.
- XenoEnergy lithium metal batteries meet the requirement of each test in the UN Manual Tests and Criteria (8 tests), Part III, subjection 38-3 through the interim tests including Altitude, Temperature, Vibration, Shock, Internal Short Circuit, Impact, Overdischarge and Forced discharge.- For shipment by sea, all of batteries are not applied for special packing based on IMDG Code 2008. Thus, all of batteries can be shipped by sea without limitation. 15. Regulatory Information N/A 16. Other Information For further information, please contact a XenoEnergy Co., Ltd. XENOENERGY CO., LTD.
470-20, Moosong-dong, Hwaseong-city, Kyonggido, Korea
Phone : (+82)-31-355-3511 Fax : (+82)-31-355-3513
5 DOLOR E INFLAMACIÓN 5.2. Fármacos antiinflamatorios no esteroidales (AINEs). 5.5. Tratamiento del dolor en cuidados paliativos. 5.1 ANALGÉSICOS-ANTIPIRÉTICOS Paracetamol Indicaciones -Dolor: El uso de paracetamol p.e. en el alivio del dolor producido por artrosis a menudo permite evitar la administración Apotex, Genfar, Grufar, Espibena, Laproff, Quifatex, Quilab, Far
Fármacia Botica Ouro Preto – relação das principais matérias-prima Relação das principais matérias-primas disponíveis na Farmácia Botica Ouro Preto. Na hipótese de não encontrar listada alguma substância que você procura, entre em contato que teremos o maior prazer em atendê-lo. Insumos ativos de uso interno (via oral): Ác. Acetil Salicílico Ac. Alfa lipóico Ác.