Combustible Gas and Vapors Combustible Gas Detector 0-100% LEL
Continuous LCD shows real-time gas concentration with
backlight in low light (auto); in alarm (auto) and on demand
Compact (1.5 x 2.0 x 3.75 in / 38.5 x 50 x 95 mm) and
Provides 90 dB tone and bright LED indication on alarm
Peak value displayed on command in % LEL
LOW and HIGH alarms with adjustable setpoints
User fi eld options include: Pass Code Protection, Latching
Equipped with a plug-in replaceable sensor
Powered by a integral rechargeable lithium ion battery
Intrinsically safe to U.S., European and Canadian standards
Full function self-test of: sensor, battery and circuitry
Pocket/belt clip, test cap and hose, battery, charger and
nATEX X g and others GasAlert LEL Detectors GA-W*
GasAlert LEL detector with internal vibrator alarm
GasAlert LEL SamplerPak Includes GasAlert LEL detector with Sampler motorized pump, 10 ft. / 3 m sampling hose and two sampling tubes in a carrying case. GA(A)-W-SK* GasAlert
GasAlert LEL SamplerPak with charger/battery kit
Accessories and Spares GA-TS03 NEW5-Port Multi-Charger
Multi-unit charger with 110 VAC main plug*
*Note: Add suffi x for delivery with 220 VAC charger:Europe: -EU
www.gasmonitors.com Email: info@bwtnet.com SPECIFICATIONS GasAlert LEL DETECTOR: 0-100% LEL Measuring GasAlert LEL: 1Low Level 1High Level Over Range
1Factory defaults are shown. Alarm levels are fi eld adjustable.
Low light (auto); alarm condition (auto); on demand
Verifi es integrity of sensor, circuitry and battery; audible/visual alarms
Catalytic bead. Poison resistant (equipped with fi lters to eliminate the poisoning
effects of silicone vapors and sulfur compounds).
advanced microcontroller and is equipped
IINDICATORS AND ALARMS:
Clearly advises alarm levels both visually and audibly
with a plug-in, poison resistant catalytic
Wide-angled alarm lens, plus alarm LCD readout
High-output, pulsing 90 dB at 1 ft. / 0.3 m (typical)
bead sensor and high output audible/visual
Pass Code Protection, Latching High Alarm and Confi dence Beep
The Over Limit alarm is latching and must
Vibrates in sync with audible and visual alarms
be acknowledged by the user to shut it OFF. User fi eld options include Pass
CONTINUOUS LCD DISPLAY:
Alphanumeric gas readout and status display advises:
Continuously displays gas concentration present
Code Protection, Latching High Alarm and
Records and displays peak (maximum) exposure to gas on demand
Displayed on activation (auto) and on demand in %
Full function self-test on activation (auto)
gas concentrations and the instrument’s
GENERAL SPECIFICATIONS:
status at all times. The full function self-
test verifi es sensor, circuitry and battery
integrity and activates the audible/visual
alarms each time you turn the instrument
Up to 14 hours per charge; 500 to 600 charges
1.5 x 2.0 x 3.75 inches / 38.5 x 50 x 95 mm
gas hazard present—Low and High gas alarms. Recorded Peak exposures can be
WARRANTY: DUE TO ONGOING RESEARCH AND PRODUCT IMPROVEMENT, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.RATINGS AND CERTIFICATIONS: ATEX: CE g II 2 G : Class I, Div. 1, Gr. A, B, C, D BAM: 03 ATEX 0001 x
X: European Conformity
protection available today. Delivered ready
T-Code: N.A. T3C Europe
for use, simply clip the instrument to your pocket or belt for unequalled protection. For further information: 1-888-749-8878 USA 1-800-663-4164 Canada +44 (0) 1869 233004 Europe
Full Information STATUS Panel with easy prompts:
+971-4-8871766 Middle +61-7-3818-8244 Australia +852-2974-1783 China +1-403-248-9226 Other Countries Corporate Headquarters
Phone: +1-403-248-9226Fax: +1-403-273-3708
Locally distributed by: www.gasmonitors.com
เอกสารกํากับยาภาษาอังกฤษ VAXIGRIP Suspension for injection 2010 strains INFLUENZA VACCINE (SPLIT VIRION, INACTIVATED) Read all of this leaflet carefully before you or your child is vaccinated. - Keep this leaflet. You may need to read it again. If you have any further questions, ask your doctor or pharmacist. This medicine
El doctor A. Fernández Cruz, Catedrático y Jefe del Servicio de Medicina Interna del Hospital Clínico San Carlos de Madrid, participa el próximo 9 y 10 de mayo en una reunión internacional sobre óxido nítrico que organizan la Sociedad Española de Hipertensión-Liga Española para la Lucha contra la Hipertensión Arterial (SEH-LELHA) y Área Científica Menarini en Barcelona. La princi