Report No.: LDBG-MSDS-1203150101 Report ID: Page 1 of 6
Material Safety Data Sheet 1. Identification of the Substances/Preparation and of the Company/Undertaking Product Details Trade Name: Power Tool Battery Manufacturer/Supplier: UNIQSTYLE MEGA INDUSTRY (HK) LIMITED Building F, No.3 Industrial Area, LongGuang District, Shenzhen City, Guangdong Province, China Contact Person: Wright E–Mail:Viooo_digital_tech@vip.163.com Tel: +86-755-21634067 Fax:+86-755-21140402 Further Information Obtainable from: UNIQSTYLE MEGA INDUSTRY (HK) LIMITED Information in Case of Emergency Tel: +86-13925229416 Contact Person: Wright 2. Composition/Information on Ingredients IMPORTANT NOTE: The battery should not be opened or burned. Exposure to the ingredients contained within or their combustion products could be harmful. Chemical Characterization: Mixture, consisting of the following components Ingredient / Substance CAS# Weight %
This document shall not be reproduced except in full without written approval by the laboratory. The result(s) shown in this test re-port refer(s) only to the sample(s) tested. If you want to search the report item, you can enter in www.ltlab.com.cn then input ID number. ZHEJIANG LANDER STANDARD TECHNOLOGY CO., LTD. ADD: No.160,11th Avenue South, Economic & Technological Development Zone, Hangzhou , Zhejiang Province 310018 TEL:+(86) 571 86043999 FAX:+(86) 571 87906666 Free Line:800 8571 758 http://www.ltlab.com.cn E-mail:info@ltlab.com.cn
Report No.: LDBG-MSDS-1203150101 Report ID: Page 2 of 6
Electrochemical system: Positive Electrode: Lithium cobaltite (LiCoO2) Electrolyte: Solution of lithium hexafluorophosphate (LiPF6) in a mixture of organic solvents. Note: The battery is contained in a hermetically-sealed case, designed to withstand temperatures and pressures encountered during normal use. As a result, during normal use, hazardous materials are fully contained inside the battery cell. The battery cell should not be opened or exposed to heat because exposure to the following ingredi-ents contained within could be harmful under some circumstances. The above information is provided for the 3. Hazards Identification
Overview: Battery is considered as sealed non-spillable one. Under normal operating conditions, the materi- als sealed inside should not be hazardous to people’s health. Only when these materials exposed during produc-tion or under case broken condition or being extremely heated (fired) or abuse, they may be hazardous to people’s Potential Health Effects Eye Contact: Contact with battery contents may cause irritation and chemical burns. Skin Contact: Contact with battery contents may cause skin irritation and/or chemical burns. Inhalation: Contents of an open battery can cause respiratory irritation and edema. Ingestion: Contents of an open battery can cause serious chemical burns of mouth, esophagus, and gastroin- 4. First-Aid Measures In case of battery rupture or explosion, evacuate personnel from contaminated area and provide maximum ventilation to clear out corrosive fumes/gases and pungent odour. Eye Contact: If battery is leaking and material contacts the eye, flush immediately with water for 15 minutes. Seek immediate medical attention. Skin Contact: If battery is leaking and material contacts the skin, remove any contaminated clothing and flush exposed skin with copious amounts of running water for at least 15 minutes. If irritation, injury or pain persists. Inhalation: If battery is leaking, contents may be irritating to respiratory passages. Move to fresh air. If irritation persists, seek medical attention. Ingestion:If battery is swallowed seek immediate medical advice. Do not induce vomiting. 5. Fire-Fighting Measures
Fire and Explosion Hazards: The battery can leak and/or spout vaporized or decomposed and combustible electrolyte fumes in case of exposure above 70℃ resulting from inappropriate use or the environment.
This document shall not be reproduced except in full without written approval by the laboratory. The result(s) shown in this test re-port refer(s) only to the sample(s) tested. If you want to search the report item, you can enter in www.ltlab.com.cn then input ID number. ZHEJIANG LANDER STANDARD TECHNOLOGY CO., LTD. ADD: No.160,11th Avenue South, Economic & Technological Development Zone, Hangzhou , Zhejiang Province 310018 TEL:+(86) 571 86043999 FAX:+(86) 571 87906666 Free Line:800 8571 758 http://www.ltlab.com.cn E-mail:info@ltlab.com.cn
Report No.: LDBG-MSDS-1203150101 Report ID: Page 3 of 6
Extinguishing Media: Use carbon dioxide, dry chemical or foam extinguishers. Hazardous Combustion Products: Thermal degradation may produce hazardous metal fumes of lithium, and Special Protective Equipment for Firefighters: In case of fires with large quantities of batteries, firefighters should wear positive pressure self-contained breathing apparatus and full protective clothing. Fight fire from a 6. Accidental Release Measures
Personal Precautions: In case of large spills, Remove personnel from area until fumes dissipate. Clean-up personnel should wear appropriate protective clothing to avoid eye and skin contact and inhalation of vapors or Methods for Cleaning Up: In the event of a battery rupture, Do not breathe vapours or touch liquid with bare hands. Sand or earth should be used to absorb any exuded material and carefully collect all released material in a plastic lined metal container. Dispose of as special waste in accordance with local regulations. Room ventilation may be required in areas where there are open or leaking batteries. 7. Handling and Storage
z When packing the batteries, do not allow battery terminals to contact each other, or contact with other
z Be sure to pack batteries by providing partitions in the packaging box, or in a separate plastic bag so that the single batteries are not mixed together.
z Use strong material for packaging boxes so that they will not be damaged by vibration, impact, dropping and stacking during their transportation.
z Do not let water penetrate into packaging boxes during their storage and transportation. z The batteries will be stored at room temperature, charged to about 30-50% of capacity. z Do not store the battery in places of the high temperature exceeding 35℃ or under direct sunlight or in front of a stove .please also avoid the places of high humidity. Be sure not to expose the battery to con-densation, water drop of not to store it under frozen condition.
z Batteries are sure to be packed in such a way as to prevent short circuits under conditions normally en-
z Please avoid storing the battery in the places where it is exposed to the static electricity. Handling: Electrical or mechanical abuse must be avoided. Do not short, respect polarity. Batteries may ex- plode or vent if they are recharged, crushed, disassembled or exposed to high temperatures. Do not mix fresh and partially discharged batteries in the same equipment. Avoid short circuits between battery terminals. Storage: Store at room temperature in dry place. (Temperature above 70℃ may result in battery leakage and rupture) Keep away from fire, sparks and heat. Avoid damage to battery case. Keep batteries in original packag-ing until use and do not jumble them.
This document shall not be reproduced except in full without written approval by the laboratory. The result(s) shown in this test re-port refer(s) only to the sample(s) tested. If you want to search the report item, you can enter in www.ltlab.com.cn then input ID number. ZHEJIANG LANDER STANDARD TECHNOLOGY CO., LTD. ADD: No.160,11th Avenue South, Economic & Technological Development Zone, Hangzhou , Zhejiang Province 310018 TEL:+(86) 571 86043999 FAX:+(86) 571 87906666 Free Line:800 8571 758 http://www.ltlab.com.cn E-mail:info@ltlab.com.cn
Report No.: LDBG-MSDS-1203150101 Report ID: Page 4 of 6
8. Exposure Controls/Personal Protection
Ventilation Requirement:No special ventilation is needed for normal use. Personal Protective Equipment: Skin Protection: None required for normal use. Use gloves when handling leaking batteries. Eye Protection: None required for normal use. Wear safety goggles when handling leaking batteries. Respiration Protection: None required for normal use. General safety and hygiene: Use only as directed. 9. Physical and Chemical Properties
General Information Odor: Appearance: Small prismatic metal cylinders, hermetically sealed and fitted with an extemal plastic sleeving. Temperature range In storage -40℃/+70℃ (Occasional)-30℃/+70℃ (Continuous)During discharge -40℃/+70℃ (Occasional)0℃/+50℃ (Continuous)During charge 10. Stability and Reactivity
Stability: The batteries are stable under normal operating conditions. Incompatibility (Materials to Avoid): The batteries are encased in a non-reactive container. Conditions to Avoid: Do not heat (above 70℃ ), crush, disassemble, short circuit or recharge. Prolonged Hazardous Decomposition Products: Corrosive/Irritant Hydrogen fluoride (HF) is produced . 11. Toxicological Information Under normal conditions of use, the batteries are non-toxic. Unless battery ruptures. In the event of exposure to intemal contents, causes skin/eye/ mucous membranes irritation. Acute Toxicity Acute Health Hazards Chronic Effects: The chemicals in this product are contained in a sealed can and exposure does not occur during normal handling and use. No chronic effects would be expected from handling a leaking battery. Carcinogenic Effects: Not currently known.
This document shall not be reproduced except in full without written approval by the laboratory. The result(s) shown in this test re-port refer(s) only to the sample(s) tested. If you want to search the report item, you can enter in www.ltlab.com.cn then input ID number. ZHEJIANG LANDER STANDARD TECHNOLOGY CO., LTD. ADD: No.160,11th Avenue South, Economic & Technological Development Zone, Hangzhou , Zhejiang Province 310018 TEL:+(86) 571 86043999 FAX:+(86) 571 87906666 Free Line:800 8571 758 http://www.ltlab.com.cn E-mail:info@ltlab.com.cn
Report No.: LDBG-MSDS-1203150101 Report ID: Page 5 of 6
Epidemiology: Not currently known. Mutagenic Effects: Not currently known. Reproductive Toxicity: Not currently known. 12. Ecological Information General Product Information: z When properly used or disposed the battery does not present environmental hazard. z Do not let internal components enter marine environment. Avoid release to waterways, wastewater or 13. Disposal Considerations
z Dispose in accordance with applicable regulations in country and state. z Disposal should be performed by permitted, professional disposal firms knowledgeable in Federal, State or Local requirements of hazardous waste treatment and hazardous waste transportation.
z Incineration should never be performed by battery users, but eventually by trained professional in au-thorized facility with proper gas and fume treatment.
z Battery recycling should be done in authorized facility. 14. Transport Information
Proper Name: LITHIUM BATTERIES / LITHIUM BATTERIES CONTAINED IN EQUIPMENT or LITHIUM BATTERIES PACKED WITH EQUIPMENT UN Number: 3090 / 3091 UN Packing Group:Ⅱ 15. Regulatory Information
z All the cells and batteries are defined as “articles” and thus are exempt from the requirements of the Hazard
z The internal component is hazardous under the criteria of the Federal OHSA Hazard Communication Standard
z UN Recommendation on the Transportation of Dangerous Goods Model Regulations. z Federal Resister/Vo1.65.No.174/Thursday, September 7,2000/Notices. z IATA Dangerous Goods Regulations 52th Effective 1 January 2011 z TLVs and BEls 1999 ACGIH z Restricted &Complied to SectionⅡ of PI965- PI967 by IATA/ICAO
This document shall not be reproduced except in full without written approval by the laboratory. The result(s) shown in this test re-port refer(s) only to the sample(s) tested. If you want to search the report item, you can enter in www.ltlab.com.cn then input ID number. ZHEJIANG LANDER STANDARD TECHNOLOGY CO., LTD. ADD: No.160,11th Avenue South, Economic & Technological Development Zone, Hangzhou , Zhejiang Province 310018 TEL:+(86) 571 86043999 FAX:+(86) 571 87906666 Free Line:800 8571 758 http://www.ltlab.com.cn E-mail:info@ltlab.com.cn
Report No.: LDBG-MSDS-1203150101 Report ID: Page 6 of 6
16. Other Information Further Information:
·This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. Department Issuing MSDS: UNIQSTYLE MEGA INDUSTRY (HK) LIMITED Issue Date: March 21, 2012
This MSDS Service is Provided by ZHEJIANG LANDER STANDARD TECHNOLOGY CO., LTD.
****************End****************
This document shall not be reproduced except in full without written approval by the laboratory. The result(s) shown in this test re-port refer(s) only to the sample(s) tested. If you want to search the report item, you can enter in www.ltlab.com.cn then input ID number. ZHEJIANG LANDER STANDARD TECHNOLOGY CO., LTD. ADD: No.160,11th Avenue South, Economic & Technological Development Zone, Hangzhou , Zhejiang Province 310018 TEL:+(86) 571 86043999 FAX:+(86) 571 87906666 Free Line:800 8571 758 http://www.ltlab.com.cn E-mail:info@ltlab.com.cn
Use of Complementary Therapies in the Treatment of Rheumatoid Arthritis Article by Louise Joel BHSc (comp med) Adv Dip Nat, Adv Dip Herb Med. 2009 Complementary therapies for rheumatoid arthritis include naturopathy, herbal medicine, psychological approaches and a number of other treatment modalities. Nutritional and dietary therapies are a well-researched area of management for rheumatoid a
SAFETY DATA SHEET LITHIUM EP3 GREASE 1) IDENTIFICATION OF THE SUBSTANCE / AND THE COMPANY / UNDERTAKING. Product Name: LITHIUM GREASE EP 3 Chemical Family: Petroleum Based Lubricating Grease. Use: Multi-purpose Industrial Lubrication. Manufacturer / Supplier: Global Lubricants Limited. Address: 13 Sandwell Business Development Centre, Oldbury Road, Smeth